RF Signal Output
Output Power 100W (50 to 100W adjustable in steps of 1 Watt)
Frequency Band 108.00MHz to 117.975 MHz
Channel pattern 50kHz
Carrier Frequency Stability ± 0.002%
Antenna System 1 + 48 Alford loops
Polarisation Horizontal
Bearing accuracy (for all elevation angle from 0 to > 40 deg.) Typically ± 0.5 deg Maximum error
Reference Phase Modulation (AM)
Frequency 30 Hz ± 0.01%
Reference Phase Shift 0 - 359.9 deg programmable in steps of 0.1 deg
Carrier Phase Stability < ± 0.5 deg referred to Ref. Generator
Variable Phase Modulation (AM)
Sub-Carrier frequency 9960 Hz ± 0.02%
Mean depth of modulation by sub-carrier 28% to 32% (adjustable)
Frequency of modulation 30Hz ± 0.01%
Deviation Ratio 16 ± 1
Voice Modulation (AM)
Frequency range 300 to 3000Hz
Modulation depth Recommended 10% (adjustable 0 to 15%)
Noise due to signal communication Negligible
Identification
Modulation Tone 1020 Hz ± 50 Hz
Modulation Depth Recommended 10% (adjustable 0-15% in steps of 1%)
Code International Morse up to three letters
Keying Speed 7 Words per minute (adjustable)
Repetition Rate 6 Words per minute (adjustable)
DME Keying Facility provided for interfacing with collocated DME or TACAN
Monitoring Alarm Conditions
Monitor Configuration Dual with one or two monitor dipoles, voting AND/OR
Change in transmitted bearing information Adjustable in 0.1 deg
Steps to a maximum of ± 1 deg
Depth of modulation of sub carrier and 30 Hz AM Adjustable from 25% to 32%
Code Failure Continuous or absent tone
Failure of antennas Alarm for failure of two diametrically opposite antennas
Failure of monitor Integral alarm
Carrier power Alarm if power <45W
Monitor Signal processing Through micro-controllers programmable alarm limits as above
Alarm delay Programmable from 1 to 90 sec
Monitor calibration Control Available through BITE and PC
Performance Monitoring Status Data on system elements can be displayed through Remote PC and RMM Software
Fault Diagnosis Down to LRU Level through fault bits
Power Supply Status Mains and BCPS status displayed as OK/NOT OK
Input Power
Primary Supply 230/110 VAC, 50/60 Hz
Power consumption

900 VA (typical) excluding battery charging

1200 VA (typical) including battery charging

Secondary Supply DC 22V to 28V DC, nominal 24V
Standby Battery Maintenance free 24V
Environmental Conditions
Indoor Equipment 0 deg C to + 50 deg C
Relative Humidity Up to 95% (0 to 35 deg)
Outdoor Equipment -50 deg C to + 70 deg C
160 Km/h (100 Mph) wind velocity
Hail stones/Ice Up to 1cm diameter without damage to antenna radome

EMC: Compliant with EMC Directive 89/336/EEC

2070 DVOR adjustment is achieved via the Remote and/or Local Maintainence Monitoring and Control PC.

The Company reserves the right to change specifications without notice.